DC Servomotor Phase-Lead Controller
The goal was a controller that brings a DC servomotor to 10% overshoot and a 0.3 s settling time. I designed a phase-lead compensator by root locus, checked it in MATLAB, and we tested it on the motor through Simulink.
Design
The plant is G(s) = 31.74 / (s(0.0976s + 1)), with poles at 0 and −10.25.
- From the specs: ζ = 0.591, ωn = 22.56 rad/s, which puts the desired dominant poles at −13.33 ± j18.20.
- The angle condition at that point needed 45.8° of phase lead.
- I placed the compensator zero and pole, then found the gain from the magnitude condition: Gc(s) = 1.838 (s + 13.333) / (s + 32.075).
Simulation vs. hardware
In MATLAB the closed loop settled in about 0.266 s, but overshoot came out at 15%. The extra pole and zero make it a third-order system, so the second-order formulas that set the target are only approximate.
On the real motor, the lead compensator gave 9.92% overshoot and settled in about 339 ms. That meets the overshoot spec and lands just over the 300 ms settling target. With gain only, at the same Kc, the motor overshot by 44.2% and took 675 ms to settle.
Ramp tracking
A triangle-wave ramp test measured a velocity constant of Kv = 23.08, against 24.2 predicted. That's within 5% of the model.